Solar Panel Size Calculator
Sizing is where a solar proposal can quietly go wrong. A system that is too small leaves you buying expensive evening power; one that is too large pushes midday surplus onto an export tariff worth a few cents. This calculator…
What this estimate does
Sizing is where a solar proposal can quietly go wrong. A system that is too small leaves you buying expensive evening power; one that is too large pushes midday surplus onto an export tariff worth a few cents. This calculator starts from energy, not from a target spend: it converts your bill into annual kWh, applies a state-level solar resource band, derates for inverter, wiring, soiling and temperature losses, then adjusts for orientation, pitch and shade before returning the array size in kW, a 450 W panel count and the roof area required. Because 2026 no longer offers a homeowner federal credit, the size that makes financial sense is often smaller than the size a salesperson would have proposed in 2024 — especially in net-billing states.
Your inputs
Change any default to match your bill, your quote and your utility tariff.
Household and price
Roof and solar resource
Money, financing and 25-year assumptions
Your estimate
Federal residential credit (2026)
$0.
Itemized cost
Ownership comparison · 25-year net
| Cash purchase | — |
|---|---|
| Loan (after payments) | — |
| Lease / PPA (no upfront) | — |
| Loan monthly payment | — |
The cash and loan rows both exclude any federal credit. A third-party owner, not you, may claim section 48E.
Environmental scale
| CO₂ avoided in year one | — |
|---|---|
| Mature-tree equivalent | — |
| Gasoline car miles | — |
Uses 0.855 lb CO₂/kWh (U.S. grid average), 48 lb/tree/year and 0.89 lb/mile.
25-year cumulative net cash flow
Sensitivity to utility rate escalation
| Annual escalation | Payback | 25-year net |
|---|
Year-by-year cash flow
| Year | Production kWh | Bill savings | Maintenance | Net | Cumulative |
|---|
How this is calculated
The governing relation is kW = annual kWh × target offset ÷ (peak sun hours × 365 × derate × roof factor). The roof factor is the product of an orientation multiplier (south 1.00, east/west 0.90, north 0.78), a tilt multiplier and a shading multiplier. We use 55 sq ft of usable roof per kW, which is typical for modern modules at roughly 20% efficiency. If you enter a usable roof area, the array is capped at area ÷ 55 and the shortfall is reported. Production is then the capped size multiplied back through the same specific yield, so a constrained roof can never produce more than its area allows.
A worked example
A Texas household with a $150 monthly bill at 15.91 ¢/kWh uses about 11,313 kWh a year. With the Southeast band's 5.2 peak sun hours, a 0.84 derate and a south-facing 20° roof, the specific yield is about 1,594 kWh per kW per year. A 90% offset therefore needs roughly 6.39 kW — about fourteen 450 W panels and 351 sq ft of usable roof. In Arizona, with 6.3 peak sun hours and a similar bill, the same offset needs closer to 5.2 kW. Same house, same bill, noticeably different hardware.
What this tool does not do
It cannot see your roof planes, setbacks, fire-code pathways, obstructions or structural capacity. It does not perform an hourly simulation, so it cannot capture time-of-use self-consumption or battery dispatch. For an address-level production estimate use NREL PVWatts; for a structural answer use a licensed contractor or engineer.
Practical checks before you compare quotes
- Use twelve months of bills, not one summer month.
- Measure only roof planes that are unshaded between roughly 9 am and 3 pm.
- Ask for the module wattage on the quote — panel count alone means nothing.
- Check whether your utility caps system size for net-metering eligibility.
Common mistakes
- Sizing from home square footage instead of kWh.
- Counting shaded or north-facing roof as usable area.
- Forgetting that a battery does not create energy — it shifts it.
- Assuming production never declines; we model 0.5% degradation per year.
Planning estimates only — not a quote, tax advice, legal advice or financial advice. State benchmarks are not your utility tariff. Verify every incentive with the program administrator and get at least three written installer quotes.
Frequently asked questions
How many panels do I need for a 2,000 sq ft house?
House square footage is a poor proxy — the electric bill is what matters. A $150 monthly bill at 18 ¢/kWh is about 10,000 kWh a year, which at a 0.90 offset typically needs 6–7 kW, or roughly 14–16 panels rated 450 W.
Does roof direction really change the size?
Yes. East/west arrays produce about 90% of a south-facing array in this model and north-facing about 78%. A shaded or north-facing roof needs more modules for the same annual energy — or a lower offset target.
Why does the calculator cap the size?
Because a roof is a hard physical limit. At 55 sq ft per kW, 400 sq ft of genuinely usable, unshaded roof supports about 7.3 kW. Anything beyond that has nowhere to go.
Should I size to 100% of my usage?
Only if your utility pays full retail for exports. Under net billing, oversizing often buys you a few cents per exported kWh while costing full price per watt.
Sources and further reading
- HelioCalc methodology and calculation kernel
- IRS FS-2025-05 (2026 federal credit rule)
- EIA Electric Power Monthly, Table 5.6.A, August 2026